Tests:Intraossesous sample: Difference between revisions

Tests:Intraossesous sample
No edit summary
m (Included minimum volumes)
 
(5 intermediate revisions by one other user not shown)
Line 6: Line 6:
{|class="wikitable"
{|class="wikitable"
|'''Synonym(s)'''
|'''Synonym(s)'''
|I.O sample
|I.O sample, IO, Intraoss
|-
|-
|'''Specimen'''
|'''Specimen'''
|1 x Lithium Heparin (green) tube, 1 x EDTA (purple) tube, Sealed Arterial Blood Gas Syringe
|1 x Lithium Heparin (green) tube, 1 x EDTA (purple) tube, Sealed Arterial Blood Gas Syringe
|-
|-
|'''Paediatric Specimen'''
|'''Sample Type'''
|
|Whole blood aspirate for CBC, Plasma or Serum for biochemistry tests
|-
|-
|'''Minimum Volumes'''
|'''Minimum Volumes'''
|200 uL for Biochemistry, 250 uL for CBC
|350 uL for Biochemistry, 250 uL for CBC
|-
|-
|'''Add-on conditions'''
|'''Add-on conditions'''
Line 33: Line 33:
|-
|-
|'''Registration Code'''
|'''Registration Code'''
|
|CBCD, FLUD
|-
|-
|'''Deletion Code'''
|'''Deletion Code'''
Line 39: Line 39:
|-
|-
|'''Useful Information'''
|'''Useful Information'''
|
|Intraosseous samples are not suitable for full analyte testing:
Haematology - The only reportable analytes are: '''Haemoglobin''' and '''Haematocrit only''' (Special Correction Procedures SOP). No coagulation testing available.
Biochemistry - Do not put intraosseous samples through the Blood gas analyser as whole blood. 
 
Run as Fluid Chemistry. The only reportable analytes are: '''Sodium, Chloride, Glucose, Calcium, Urea, Creatinine, Albumin, Total protein, and pH only.'''
|-
|-
|'''Measurement Uncertainty'''
|'''Measurement Uncertainty'''
|N/A
|N/A
|}
|}

Latest revision as of 20:47, 1 April 2026


Synonym(s) I.O sample, IO, Intraoss
Specimen 1 x Lithium Heparin (green) tube, 1 x EDTA (purple) tube, Sealed Arterial Blood Gas Syringe
Sample Type Whole blood aspirate for CBC, Plasma or Serum for biochemistry tests
Minimum Volumes 350 uL for Biochemistry, 250 uL for CBC
Add-on conditions N/A
Test Availability Mon - Sun, 24 hours
Turnaround Time Hastings 1 - 2.5 hours
Where analysed Hastings
Department Biochemistry ext. 2448, Haematology ext.2445
Registration Code CBCD, FLUD
Deletion Code N/A
Useful Information Intraosseous samples are not suitable for full analyte testing:

Haematology - The only reportable analytes are: Haemoglobin and Haematocrit only (Special Correction Procedures SOP). No coagulation testing available.

Biochemistry - Do not put intraosseous samples through the Blood gas analyser as whole blood.

Run as Fluid Chemistry. The only reportable analytes are: Sodium, Chloride, Glucose, Calcium, Urea, Creatinine, Albumin, Total protein, and pH only.

Measurement Uncertainty N/A