Tests:Factor VIII Inhibitor assay: Difference between revisions

From Te Matau a Māui | Laboratory Services
Tests:Factor VIII Inhibitor assay
Jump to navigation Jump to search
No edit summary
mNo edit summary
 
(2 intermediate revisions by 2 users not shown)
Line 10: Line 10:
|-
|-
|'''Specimen'''
|'''Specimen'''
|2.7 mL sodium citrate tubes ONLY (Must be FULL)
|2 X 2.7 mL sodium citrate tubes ONLY (Must be FULL)
|-
|-
|'''Paediatric Specimen'''
|'''Paediatric Specimen'''
|2.7 mL Sodium Citrate ONLY (Blue top - Must be FULL)
|2.7 mL Sodium Citrate ONLY (Blue top - Must be FULL)
|-
|'''Minimum Volume'''
|Citrate tubes must be FULL
Separated plasma - 2mL
|-
|-
|'''Add-on conditions'''
|'''Add-on conditions'''
Line 31: Line 35:
|-
|-
|'''Registration Code'''
|'''Registration Code'''
|HINH
|COAG
|-
|-
|'''Deletion Code'''
|'''Deletion Code'''
Line 43: Line 47:
|-
|-
|'''Lab Notes'''
|'''Lab Notes'''
|One 2.7ml citrated (BLUE top) collection tube is required. The sample is registered for a sendaway test (registration code COAG) - Refer to senior Haematology staff for advice as other testing may be required.
|This is not the same as an inhibitor <u>screen</u>, (screens are done in Hastings).  One 2.7ml citrated (BLUE top) collection tube is required. The sample is registered for a sendaway test (registration code COAG) - Refer to senior Haematology staff for advice as other testing may be required.
|}
|}

Latest revision as of 23:43, 12 May 2024


Synonym(s) Coagulation Inhibitor Assay, Bethesda, Acquired Haemophilia A
Specimen 2 X 2.7 mL sodium citrate tubes ONLY (Must be FULL)
Paediatric Specimen 2.7 mL Sodium Citrate ONLY (Blue top - Must be FULL)
Minimum Volume Citrate tubes must be FULL

Separated plasma - 2mL

Add-on conditions 4 hours @ 4°C
Test Availability Referred test - Refer to CHL website
Turnaround Time Referred test - Refer to CHL website
Where analysed CHL
Department Haematology, (06) 878 1308 ext. 2445
Registration Code COAG
Deletion Code 7182
Useful Information
Measurement Uncertainty N/A
Lab Notes This is not the same as an inhibitor screen, (screens are done in Hastings). One 2.7ml citrated (BLUE top) collection tube is required. The sample is registered for a sendaway test (registration code COAG) - Refer to senior Haematology staff for advice as other testing may be required.